1.
Sci Rep ; 14(1): 8352, 2024 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594267

RESUMO

Photoacoustic Spectroscopy (PAS) is a potential method for the noninvasive detection of blood glucose. However random blood glucose testing can help to diagnose diabetes at an early stage and is crucial for managing and preventing complications with diabetes. In order to improve the diagnosis, control, and treatment of Diabetes Mellitus, an appropriate approach of noninvasive random blood glucose is required for glucose monitoring. A polynomial kernel-based ridge regression is proposed in this paper to detect random blood glucose accurately using PAS. Additionally, we explored the impact of the biological parameter BMI on the regulation of blood glucose, as it serves as the primary source of energy for the body's cells. The kernel function plays a pivotal role in kernel ridge regression as it enables the algorithm to capture intricate non-linear associations between input and output variables. Using a Pulsed Laser source with a wavelength of 905 nm, a noninvasive portable device has been developed to collect the Photoacoustic (PA) signal from a finger. A collection of 105 individual random blood glucose samples was obtained and their accuracy was assessed using three metrics: Root Mean Square Error (RMSE), Mean Absolute Difference (MAD), and Mean Absolute Relative Difference (MARD). The respective values for these metrics were found to be 10.94 (mg/dl), 10.15 (mg/dl), and 8.86%. The performance of the readings was evaluated through Clarke Error Grid Analysis and Bland Altman Plot, demonstrating that the obtained readings outperformed the previously reported state-of-the-art approaches. To conclude the proposed IoT-based PAS random blood glucose monitoring system using kernel-based ridge regression is reported for the first time with more accuracy.


Assuntos
Glicemia , Diabetes Mellitus , Humanos , Glicemia/análise , Automonitorização da Glicemia/métodos , Monitorização Fisiológica/métodos , Análise Espectral
2.
J Med Syst ; 48(1): 46, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656727

RESUMO

BACKGROUND: Preterm neonates are extensively monitored to require strict oxygen target attainment for optimal outcomes. In daily practice, detailed oxygenation data are hardly used and crucial patterns may be missed due to the snapshot presentations and subjective observations. This study aimed to develop a web-based dashboard with both detailed and summarized oxygenation data in real-time and to test its feasibility to support clinical decision making. METHODS: Data from pulse oximeters and ventilators were synchronized and stored to enable real-time and retrospective trend visualizations in a web-based viewer. The dashboard was designed based on interviews with clinicians. A preliminary version was evaluated during daily clinical rounds. The routine evaluation of the respiratory condition of neonates (gestational age < 32 weeks) with respiratory support at the NICU was compared to an assessment with the assistance of the dashboard. RESULTS: The web-based dashboard included data on the oxygen saturation (SpO2), fraction of inspired oxygen (FiO2), SpO2/FiO2 ratio, and area < 80% and > 95% SpO2 curve during time intervals that could be varied. The distribution of SpO2 values was visualized as histograms. In 65% of the patient evaluations (n = 86) the level of hypoxia was assessed differently with the use of the dashboard. In 75% of the patients the dashboard was judged to provide added value for the clinicians in supporting clinical decisions. CONCLUSIONS: A web-based customized oxygenation dashboard for preterm neonates at the NICU was developed and found feasible during evaluation. More clear and objective information was found supportive for clinicians during the daily rounds in tailoring treatment strategies.


Assuntos
Recém-Nascido Prematuro , Internet , Oximetria , Melhoria de Qualidade , Humanos , Recém-Nascido , Melhoria de Qualidade/organização & administração , Oximetria/métodos , Saturação de Oxigênio , Unidades de Terapia Intensiva Neonatal , Monitorização Fisiológica/métodos
3.
Crit Care ; 28(1): 104, 2024 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561829

RESUMO

Severe acute brain injuries, stemming from trauma, ischemia or hemorrhage, remain a significant global healthcare concern due to their association with high morbidity and mortality rates. Accurate assessment of secondary brain injuries severity is pivotal for tailor adequate therapies in such patients. Together with neurological examination and brain imaging, monitoring of systemic secondary brain injuries is relatively straightforward and should be implemented in all patients, according to local resources. Cerebral secondary injuries involve factors like brain compliance loss, tissue hypoxia, seizures, metabolic disturbances and neuroinflammation. In this viewpoint, we have considered the combination of specific noninvasive and invasive monitoring tools to better understand the mechanisms behind the occurrence of these events and enhance treatment customization, such as intracranial pressure monitoring, brain oxygenation assessment and metabolic monitoring. These tools enable precise intervention, contributing to improved care quality for severe brain injury patients. The future entails more sophisticated technologies, necessitating knowledge, interdisciplinary collaboration and resource allocation, with a focus on patient-centered care and rigorous validation through clinical trials.


Assuntos
Lesões Encefálicas Traumáticas , Lesões Encefálicas , Adulto , Humanos , Cuidados Críticos/métodos , Pressão Intracraniana , Lesões Encefálicas/terapia , Lesões Encefálicas/complicações , Encéfalo , Monitorização Fisiológica/métodos
4.
Sensors (Basel) ; 24(6)2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38544097

RESUMO

Surface electromyography is a technique used to measure the electrical activity of muscles. sEMG can be used to assess muscle function in various settings, including clinical, academic/industrial research, and sports medicine. The aim of this study is to develop a wearable textile sensor for continuous sEMG monitoring. Here, we have developed an integrated biomedical monitoring system that records sEMG signals through a textile electrode embroidered within a smart sleeve bandage for telemetric assessment of muscle activities and fatigue. We have taken an "Internet of Things"-based approach to acquire the sEMG, using a Myoware sensor and transmit the signal wirelessly through a WiFi-enabled microcontroller unit (NodeMCU; ESP8266). Using a wireless router as an access point, the data transmitted from ESP8266 was received and routed to the webserver-cum-database (Xampp local server) installed on a mobile phone or PC for processing and visualization. The textile electrode integrated with IoT enabled us to measure sEMG, whose quality is similar to that of conventional methods. To verify the performance of our developed prototype, we compared the sEMG signal recorded from the biceps, triceps, and tibialis muscles, using both the smart textile electrode and the gelled electrode. The root mean square and average rectified values of the sEMG measured using our prototype for the three muscle types were within the range of 1.001 ± 0.091 mV to 1.025 ± 0.060 mV and 0.291 ± 0.00 mV to 0.65 ± 0.09 mV, respectively. Further, we also performed the principal component analysis for a total of 18 features (15 time domain and 3 frequency domain) for the same muscle position signals. On the basis on the hierarchical clustering analysis of the PCA's score, as well as the one-way MANOVA of the 18 features, we conclude that the differences observed in the data for the different muscle types as well as the electrode types are statistically insignificant.


Assuntos
Têxteis , Dispositivos Eletrônicos Vestíveis , Músculo Esquelético/fisiologia , Eletromiografia/métodos , Monitorização Fisiológica/métodos
5.
Clin Neurol Neurosurg ; 239: 108209, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38430649

RESUMO

Elevated intracranial pressure (ICP) is a life-threatening condition that must be promptly diagnosed. However, the gold standard methods for ICP monitoring are invasive, time-consuming, and they involve certain risks. To address these risks, many noninvasive approaches have been proposed. This study undertakes a literature review of the existing noninvasive methods, which have reported promising results. The experimental base on which they are established, however, prevents their application in emergency conditions and thus none of them are capable of replacing the traditional invasive methods to date. On the other hand, contemporary methods leverage Machine Learning (ML) which has already shown unprecedented results in several medical research areas. That said, only a few publications exist on ML-based approaches for ICP estimation, which are not appropriate for emergency conditions due to their restricted capability of employing the medical imaging data available in intensive care units. The lack of such image-based ML models to estimate ICP is attributed to the scarcity of annotated datasets requiring directly measured ICP data. This ascertainment highlights an active and unexplored scientific frontier, calling for further research and development in the field of ICP estimation, particularly leveraging the untapped potential of ML techniques.


Assuntos
Hipertensão Intracraniana , Pressão Intracraniana , Humanos , Monitorização Fisiológica/métodos , Hipertensão Intracraniana/diagnóstico , Unidades de Terapia Intensiva
6.
Sci Rep ; 14(1): 7478, 2024 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-38553509

RESUMO

This study examined the possibility of estimating cardiac output (CO) using a multimodal stacking model that utilizes cardiopulmonary interactions during general anesthesia and outlined a retrospective application of machine learning regression model to a pre-collected dataset. The data of 469 adult patients (obtained from VitalDB) with normal pulmonary function tests who underwent general anesthesia were analyzed. The hemodynamic data in this study included non-invasive blood pressure, plethysmographic heart rate, and SpO2. CO was recorded using Vigileo and EV1000 (pulse contour technique devices). Respiratory data included mechanical ventilation parameters and end-tidal CO2 levels. A generalized linear regression model was used as the metalearner for the multimodal stacking ensemble method. Random forest, generalized linear regression, gradient boosting machine, and XGBoost were used as base learners. A Bland-Altman plot revealed that the multimodal stacked ensemble model for CO prediction from 327 patients had a bias of - 0.001 L/min and - 0.271% when calculating the percentage of difference using the EV1000 device. Agreement of model CO prediction and measured Vigileo CO in 142 patients reported a bias of - 0.01 and - 0.333%. Overall, this model predicts CO compared to data obtained by the pulse contour technique CO monitors with good agreement.


Assuntos
Anestesia Geral , Adulto , Humanos , Estudos Retrospectivos , Débito Cardíaco/fisiologia , Pressão Sanguínea , Monitorização Fisiológica/métodos , Reprodutibilidade dos Testes
7.
Biosens Bioelectron ; 254: 116232, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38520984

RESUMO

Healthcare system is undergoing a significant transformation from a traditional hospital-centered to an individual-centered one, as a result of escalating chronic diseases, ageing populations, and ever-increasing healthcare costs,. Wearable sensors have become widely used in health monitoring systems since the COVID-19 pandemic. They enable continuous measurement of important health indicators like body temperature, wrist pulse, respiration rate, and non-invasive bio fluids like saliva and perspiration. Over the last few decades, the development has mostly concentrated on electrochemical and electrical wearable sensors. However, due to the drawbacks of such sensors, such as electronic waste, electromagnetic interference, non-electrical security, and poor performance, researchers are exhibiting a strong interest in optical principle-based systems. Fiber-based optical wearables are among the most promising healthcare systems because of advancements in high-sensitivity, durable, multiplexed sensing, and simple integration with flexible materials to improve wearability and simplicity. We present an overview of recent developments in optical fiber-based wearable sensors, focusing on two mechanisms: wavelength interrogation and intensity modulation for the detection of body temperature, pulse rate, respiration rate, body movements, and biomedical noninvasive fluids, with a thorough examination of their benefits and drawbacks. This review also focuses on improving working performance and application techniques for healthcare systems, including the integration of nanomaterials and the usage of the Internet of Things (IoT) with signal processing. Finally, the review concludes with a discussion of the future possibilities and problems for optical fiber-based wearables.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Humanos , Técnicas Biossensoriais/métodos , Fibras Ópticas , Pandemias , Monitorização Fisiológica/métodos
8.
Sci Rep ; 14(1): 7570, 2024 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-38555360

RESUMO

Pressure monitoring in various organs of the body is essential for appropriate diagnostic and therapeutic purposes. In almost all situations, monitoring is performed in a hospital setting. Technological advances not only promise to improve clinical pressure monitoring systems, but also engage toward the development of fully implantable systems in ambulatory patients. Such systems would not only provide longitudinal time monitoring to healthcare personnel, but also to the patient who could adjust their way-of-life in response to the measurements. In the past years, we have developed a new type of piezoresistive pressure sensor system. Different bench tests have demonstrated that it delivers precise and reliable pressure measurements in real-time. The potential of this system was confirmed by a continuous recording in a patient that lasted for almost a day. In the present study, we further characterized the functionality of this sensor system by conducting in vivo implantation experiments in nine female farm pigs. To get a step closer to a fully implantable system, we also adapted two different wireless communication solutions to the sensor system. The communication protocols are based on MICS (Medical Implant Communication System) and BLE (Bluetooth Low Energy) communication. As a proof-of-concept, implantation experiments in nine female pigs demonstrated the functionality of both systems, with a notable technical superiority of the BLE.


Assuntos
Computadores , Próteses e Implantes , Humanos , Feminino , Animais , Suínos , Monitorização Fisiológica/métodos
11.
J Neural Eng ; 21(2)2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38479008

RESUMO

Objective. The primary objective of this study was to evaluate the reliability, comfort, and performance of a custom-fit, non-invasive long-term electrophysiologic headphone, known as Aware Hearable, for the ambulatory recording of brain activities. These recordings play a crucial role in diagnosing neurological disorders such as epilepsy and in studying neural dynamics during daily activities.Approach.The study uses commercial manufacturing processes common to the hearing aid industry, such as 3D scanning, computer-aided design modeling, and 3D printing. These processes enable the creation of the Aware Hearable with a personalized, custom-fit, thereby ensuring complete and consistent contact with the inner surfaces of the ear for high-quality data recordings. Additionally, the study employs a machine learning data analysis approach to validate the recordings produced by Aware Hearable, by comparing them to the gold standard intracranial electroencephalography recordings in epilepsy patients.Main results.The results indicate the potential of Aware Hearable to expedite the diagnosis of epilepsy by enabling extended periods of ambulatory recording.Significance.This offers significant reductions in burden to patients and their families. Furthermore, the device's utility may extend to a broader spectrum, making it suitable for other applications involving neurophysiological recordings in real-world settings.


Assuntos
Eletroencefalografia , Epilepsia , Humanos , Eletroencefalografia/métodos , Reprodutibilidade dos Testes , Epilepsia/diagnóstico , Monitorização Fisiológica/métodos , Eletrocorticografia
12.
Kardiol Pol ; 82(3): 308-314, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38493457

RESUMO

BACKGROUND: Remote monitoring (RM) of cardiac implantable electronic devices for adults offers improved treatment efficacy and, consequently, better patient clinical outcomes. There is scant data on the value and prognosis of RM in the pediatric population. AIMS: The goal of this study was to determine the efficacy of RM by analyzing the connectivity of bedside transmitters, adherence to planned automatic follow-ups, and occurrence of alert-based events. METHODS: We evaluated the pediatric population with implanted pacemakers for congenital AV block or after surgically corrected congenital heart diseases. RESULTS: A total of 69 patients were included in our study. The median (Q1-Q3) patient age was 6.0 (2.0-11.0) years. All patients received bedside transmitters and were enrolled in the RM system. Among them, 95.7% of patients had their first scheduled follow-up successfully sent. Patients were followed up remotely over a median time of 33.0 (13-45) months. Only 42% of patients were continuously monitored, and all scheduled transmissions were delivered on time. Further analysis revealed that 34.8% of patients missed transmissions between June and September (holiday season). Alert-based events were observed in 40.6% patients, mainly related to epicardial lead malfunction and arrhythmic events. Overall compliance was also compromised by socioeconomic factors. CONCLUSIONS: Our findings are in concordance with recently published results by PACES regarding a high level of compliance in patient enrollment to RM and time to initial transmission. However, a lower level of adherence was observed during the holiday season due to interrupted connectivity of bedside transmitters. Importantly, a relatively low occurrence of alert transmissions was observed, mainly related to epicardial lead malfunction and arrhythmic events.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Adulto , Humanos , Criança , Tecnologia de Sensoriamento Remoto/métodos , Monitorização Fisiológica/métodos , Arritmias Cardíacas/terapia
13.
Crit Care Nurse ; 44(2): 21-30, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555968

RESUMO

BACKGROUND: Alarm fatigue among nurses working in the intensive care unit has garnered considerable attention as a national patient safety priority. A viable solution for reducing the frequency of alarms and unnecessary noise is intensive care unit alarm monitor customization. LOCAL PROBLEM: A 24-bed cardiovascular and thoracic surgery intensive care unit in a large academic medical center identified a high rate of alarms and associated noise as a problem contributing to nurse alarm fatigue. METHODS: An alarm monitor quality improvement project used both alarm frequency and nurse surveys before and after implementation to determine the effectiveness of interventions. Multimodal interventions included nurse training sessions, informational flyers, organizational policies, and an alarm monitor training video. Unexpected results inspired an extensive investigation and secondary analysis, which included examining the data-capturing capabilities of the alarm monitors and the impact of context factors. RESULTS: Alarm frequencies unexpectedly increased after the intervention. The software data-capturing features of the alarm monitors for determining frequency did not accurately measure nurse interactions with monitors. Measured increases in patient census, nurse staffing, and data input from medical devices from before to after the intervention substantially affected project results. CONCLUSIONS: Alarm frequencies proved an unreliable measure of nurse skills and practices in alarm customization. Documented changes in context factors provided strong anecdotal evidence of changed circumstances that clarified project results and underscored the critical importance of contemporaneous collection of context data. Designs and methods used in quality improvement projects must include reliable outcome measures to achieve meaningful results.


Assuntos
Fadiga de Alarmes do Pessoal de Saúde , Alarmes Clínicos , Humanos , Monitorização Fisiológica/métodos , Cuidados Críticos/métodos , Unidades de Terapia Intensiva
14.
Curr Opin Crit Care ; 30(2): 99-105, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38441121

RESUMO

PURPOSE OF REVIEW: We selectively review emerging noninvasive neuromonitoring techniques and the evidence that supports their use in the ICU setting. The focus is on neuromonitoring research in patients with acute brain injury. RECENT FINDINGS: Noninvasive intracranial pressure evaluation with optic nerve sheath diameter measurements, transcranial Doppler waveform analysis, or skull mechanical extensometer waveform recordings have potential safety and resource-intensity advantages when compared to standard invasive monitors, however each of these techniques has limitations. Quantitative electroencephalography can be applied for detection of cerebral ischemia and states of covert consciousness. Near-infrared spectroscopy may be leveraged for cerebral oxygenation and autoregulation computation. Automated quantitative pupillometry and heart rate variability analysis have been shown to have diagnostic and/or prognostic significance in selected subtypes of acute brain injury. Finally, artificial intelligence is likely to transform interpretation and deployment of neuromonitoring paradigms individually and when integrated in multimodal paradigms. SUMMARY: The ability to detect brain dysfunction and injury in critically ill patients is being enriched thanks to remarkable advances in neuromonitoring data acquisition and analysis. Studies are needed to validate the accuracy and reliability of these new approaches, and their feasibility and implementation within existing intensive care workflows.


Assuntos
Inteligência Artificial , Lesões Encefálicas , Humanos , Monitorização Fisiológica/métodos , Reprodutibilidade dos Testes , Lesões Encefálicas/diagnóstico , Unidades de Terapia Intensiva , Pressão Intracraniana/fisiologia
15.
Eur J Emerg Med ; 31(2): 98-107, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38364037

RESUMO

Intravenous fluid therapy is commonly administered in the emergency department (ED). Despite the deleterious potential of over- and under-resuscitation, professional society guidelines continue to recommend administering a fixed volume of fluid in initial resuscitation. Predicting whether a specific patient will respond to fluid therapy remains one of the most important, but challenging questions that ED clinicians face in clinical practice. Surrogate parameters (i.e. blood pressure and heart rate), are widely used in usual care to estimate changes in stroke volume (SV). Due to their inadequacy in estimating SV, noninvasive techniques (e.g. bioreactance, echocardiography, noninvasive finger cuff technology), have been proposed as a more accurate and readily deployable method for assessing flow and preload responsiveness. Dynamic monitoring systems based on cardiac preload challenge and assessment of SV, by using noninvasive and continuous methods, provide more accurate, feasible, efficient, and reasonably accurate strategy for prediction of fluid responsiveness than static measurements. In this article, we aimed to analyze the different methods currently available for dynamic monitoring of preload responsiveness.


Assuntos
Hemodinâmica , Choque , Humanos , Hemodinâmica/fisiologia , Choque/diagnóstico , Choque/terapia , Volume Sistólico/fisiologia , Ressuscitação/métodos , Hidratação/métodos , Serviço Hospitalar de Emergência , Monitorização Fisiológica/métodos
16.
Int J Med Inform ; 184: 105349, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38301520

RESUMO

BACKGROUND: Alarm fatigue is a major technology-induced hazard for patients and staff in intensive care units. Too many - mostly unnecessary - alarms cause desensitisation and lack of response in medical staff. Unsuitable alarm policies are one reason for alarm fatigue. But changing alarm policies is a delicate issue since it concerns patient safety. OBJECTIVE: We present ARTEMIS, a novel, computer-aided clinical decision support system for policy makers that can help to considerably improve alarm policies using data from hospital information systems. METHODS: Policy makers can use different policy components from ARTEMIS' internal library to assemble tailor-made alarm policies for their intensive care units. Alternatively, policy makers can provide even more highly customised policy components as Python functions using data the hospital information systems. This can even include machine learning models - for example for setting alarm thresholds. Finally, policy makers can evaluate their system of policies and compare the resulting alarm loads. RESULTS: ARTEMIS reports and compares numbers of alarms caused by different alarm policies for an easily adaptable target population. ARTEMIS can compare policies side-by-side and provides grid comparisons and heat maps for parameter optimisation. For example, we found that the utility of alarm delays varies based on target population. Furthermore, policy makers can introduce virtual parameters that are not in the original data by providing a formula to compute them. Virtual parameters help measuring and alarming on the right metric, even if the patient monitors do not directly measure this metric. CONCLUSION: ARTEMIS does not release the policy maker from assessing the policy from a medical standpoint. But as a knowledge discovery and clinical decision support system, it provides a strong quantitative foundation for medical decisions. At comparatively low cost of implementation, ARTEMIS can have a substantial impact on patients and staff alike - with organisational, economic, and clinical benefits for the implementing hospital.


Assuntos
Fadiga de Alarmes do Pessoal de Saúde , Alarmes Clínicos , Humanos , Unidades de Terapia Intensiva , Monitorização Fisiológica/métodos , Políticas
17.
Biosensors (Basel) ; 14(2)2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38392009

RESUMO

This article explores the importance of wearable and remote technologies in healthcare. The focus highlights its potential in continuous monitoring, examines the specificity of the issue, and offers a view of proactive healthcare. Our research describes a wide range of device types and scientific methodologies, starting from traditional chest belts to their modern alternatives and cutting-edge bioamplifiers that distinguish breathing from chest impedance variations. We also investigated innovative technologies such as the monitoring of thorax micromovements based on the principles of seismocardiography, ballistocardiography, remote camera recordings, deployment of integrated optical fibers, or extraction of respiration from cardiovascular variables. Our review is extended to include acoustic methods and breath and blood gas analysis, providing a comprehensive overview of different approaches to respiratory monitoring. The topic of monitoring respiration with wearable and remote electronics is currently the center of attention of researchers, which is also reflected by the growing number of publications. In our manuscript, we offer an overview of the most interesting ones.


Assuntos
Dispositivos Eletrônicos Vestíveis , Tecnologia , Respiração , Eletrônica , Monitorização Fisiológica/métodos
18.
Ned Tijdschr Geneeskd ; 1682024 02 08.
Artigo em Holandês | MEDLINE | ID: mdl-38375865

RESUMO

OBJECTIVE: To provide an overview of the effectiveness of various forms of home telemonitoring systems for heart failure and the potential role these systems may have in decreasing the burden on healthcare through reduction in heart failure hospitalizations. DESIGN: Meta-analysis of randomized and observational studies. METHODS: A meta-analysis of randomized and observational studies was carried out to assess the effect on mortality and heart failure-related hospitalizations, comparing standard heart failure care with the use of home monitoring systems. RESULTS: The pooled results from 92 studies demonstrate a reduction in the risk of both mortality and heart failure admissions. CONCLUSION: The results of this meta-analysis support the use of home telemonitoring systems. Determining which form of home telemonitoring is most suitable for which patient requires further research.


Assuntos
Insuficiência Cardíaca , Telemedicina , Humanos , Telemetria/métodos , Monitorização Fisiológica/métodos , Hospitalização , Telemedicina/métodos , Insuficiência Cardíaca/terapia
19.
Sensors (Basel) ; 24(3)2024 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-38339721

RESUMO

The use of radar technology for non-contact measurement of vital parameters is increasingly being examined in scientific studies. Based on a systematic literature search in the PubMed, German National Library, Austrian Library Network (Union Catalog), Swiss National Library and Common Library Network databases, the accuracy of heart rate and/or respiratory rate measurements by means of radar technology was analyzed. In 37% of the included studies on the measurement of the respiratory rate and in 48% of those on the measurement of the heart rate, the maximum deviation was 5%. For a tolerated deviation of 10%, the corresponding percentages were 85% and 87%, respectively. However, the quantitative comparability of the results available in the current literature is very limited due to a variety of variables. The elimination of the problem of confounding variables and the continuation of the tendency to focus on the algorithm applied will continue to constitute a central topic of radar-based vital parameter measurement. Promising fields of application of research can be found in particular in areas that require non-contact measurements. This includes infection events, emergency medicine, disaster situations and major catastrophic incidents.


Assuntos
Radar , Taxa Respiratória , Frequência Cardíaca/fisiologia , Processamento de Sinais Assistido por Computador , Algoritmos , Sinais Vitais , Monitorização Fisiológica/métodos
20.
Sensors (Basel) ; 24(4)2024 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-38400474

RESUMO

In the rapidly evolving landscape of continuous electrocardiogram (ECG) monitoring systems, there is a heightened demand for non-invasive sensors capable of measuring ECGs and detecting heart rate variability (HRV) in diverse populations, ranging from cardiovascular patients to sports enthusiasts. Challenges like device accuracy, patient privacy, signal noise, and long-term safety impede the use of wearable devices in clinical practice. This scoping review aims to assess the performance and safety of novel multi-channel, sensor-based biopotential wearable devices in adults. A comprehensive search strategy was employed on four databases, resulting in 143 records and the inclusion of 12 relevant studies. Most studies focused on healthy adult subjects (n = 6), with some examining controlled groups with atrial fibrillation (AF) (n = 3), long QT syndrome (n = 1), and sleep apnea (n = 1). The investigated bio-sensor devices included chest-worn belts (n = 2), wrist bands (n = 2), adhesive chest strips (n = 2), and wearable textile smart clothes (n = 4). The primary objective of the included studies was to evaluate device performance in terms of accuracy, signal quality, comparability, and visual assessment of ECGs. Safety findings, reported in five articles, indicated no major side effects for long-term/continuous monitoring, with only minor instances of skin irritation. Looking forward, there are ample opportunities to enhance and test these technologies across various physical activity intensities and clinical conditions.


Assuntos
Fibrilação Atrial , Dispositivos Eletrônicos Vestíveis , Adulto , Humanos , Eletrocardiografia , Frequência Cardíaca/fisiologia , Monitorização Fisiológica/métodos